SRC | What You Should Do |
11 A6xx xxxx | Licensed Internal Code intervention is needed. 1. Look at characters 5 through 8 of the top 16 character line of function 11 (4 rightmost characters of word 1). These 4 characters are the unit reference code. 2. See the following table (Table 2) and find the unit reference code. |
11 B6xx xxxx | The Licensed Internal Code detected a failure. 1. Look at characters 5 through 8 of the top 16 character line of function 11 (4 rightmost characters of word 1). These 4 characters are the unit reference code. 2. See the following table (Table 2) and find the unit reference code. 3. When working with the Product Activity Log, System Licensed Internal Code entries often occur as a secondary effect of other hardware related entries. The following list is a suggested method of isolating these kinds of problems. a. Examine the date and time of the informational reference codes. b. Determine if any other reference codes were logged at or before the same date and time. c. Start the service approach based on these other logged errors. |
For more on the Failing Item column entries, see Table 3. Licensed Internal Code failing items details, which follows the reference code table below.
Table 2. (A6xx, B6xx) Licensed Internal Code reference codes
Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
0000 | Operating system status code This reference code is for information only. It is shown in the Product activity log as a side effect of a condition that was detected by LIC. Normally, no action should be taken as a result of information reference codes. However, to isolate the root cause, use these suggestions: | |
0102 | A machine check occurred during IPL Words 2 to 9 of this SRC contain additional diagnostic information. Record SRC words 1 through 9 before attempting to IPL again and report the problem to your Software Service Provider. | |
0103 | Main storage dump must be copied for service. Perform LICIP01. | |
0104 | Terminate Immediate reference code is bad Perform LICIP08. | AJDG301 |
0105 | More than one request to terminate the system was issued Perform LICIP08. | AJDG301 |
0106 | Terminate Immediate data is not valid Perform LICIP08. | AJDG301 |
0107 | Main storage dump must be copied for service. The server detected an unrecoverable machine check condition. Collect all the words of the SRC and the main store dump and send to your system manufacturer for analysis. | |
0109 | An unrecoverable memory error occurred Re-IPL the partition that terminated. Then, look for and correct errors with SRCs of the form B1xxxxxx in the Serviceable Event View that indicate the replacement of memory in the failing item list. If there are no B1xxxxxx SRCs in the Serviceable Event View that indicate a memory problem, perform a slow boot in order to run diagnostics on the memory. Then, look for and correct erros with SRCs of the form B1xxxxxx in the Serviceable Event View. | SVCDOCS |
0202 | Unrecoverable read error Restore the Licensed Internal Code using "Licensed Internal Code Install and Restore" in the iSeries™ Service Functions information. | |
0210 | The system ASP has run out of disk storage The out of storage condition in the system ASP can be caused by an allocation failure in some other system software. This could be a looping condition that continues to allocate storage. Contact your service representative for assistance with the Main Storage Dump. | |
0231 | Disk sanitize action completed successfully No service action required. This entry is logged for information only. | |
0232 | Disk sanitize action did not complete successfully Provide the Product Activity Log entry to your next level of support for analysis. | |
0244, 0255, 0266 | Contact was lost with the device indicated Do not power off the system. Perform LICIP13. | FI00580 FI00500 FI00302 FI00301 AJDG301 |
0277 | A compression disk unit cannot complete an operation. Note: Look at the 4 leftmost characters of the Data display for word 7. These four characters indicate the type of problem that exists and the recovery action to perform. If these characters are 8402 or 2002, the compression disk unit is temporarily full of data. The command to the compression disk is being held. When the storage subsystem controller has created sufficient space on the compression disk unit to contain the data, the command which is being held will be released and the system will resume normal processing. If the system does not resume normal processing within 20 minutes, contact your next level of support. If these characters are 8400 or 2000, the compression disk unit is full of data. The command to the compression disk is being held. The customer should perform the recovery actions specified in "Disk Unit Full Considerations" in the Backup and Recovery Guide . | |
0302 | Recursion in exception handler Perform LICIP08. | AJDG301 |
0304 | Component specific exception handler return code not valid Perform LICIP08. | AJDG301 |
0305 | Exception while storage management lock is held Perform LICIP08. | AJDG301 |
0307 to 0308 | LIC exception code detected a problem Component Specific Exception Handler recursion is detected in an OS/400 process. Perform LICIP08. | AJDG301 |
0317 | Traceback for code not found Perform LICIP08. | AJDG301 |
0323 to 0329 | LIC exception code detected a problem Perform LICIP08. | AJDG301 |
0333 | A branch to a bad address was attempted Perform LICIP08. | AJDG301 |
0334 | Exception Handler could not be removed Perform LICIP08. | AJDG301 |
0335 | Code resumed to not valid address following exception Perform LICIP08. | AJDG301 |
0401 | A machine check occurred during IPL Perform LICIP08. | AJDG301 |
0402 | A machine check occurred during authority initialization Perform LICIP08. | AJDG301 |
0403 | Unhandled exception during IPL or install Perform LICIP08. | AJDG301 |
0405 | Unhandled exception in authority recovery Perform LICIP08. | AJDG301 |
0406 | Unhandled exception in data base recovery Perform LICIP08. | AJDG301 |
0407 | Unhandled exception in data base initialization Perform LICIP08. | AJDG301 |
0408 | Unhandled exception in journal recovery Perform LICIP08. | AJDG301 |
0409 | Unhandled exception in journal synchronization Perform LICIP08. | AJDG301 |
0410 | Unhandled exception in journal clean up Perform LICIP08. | AJDG301 |
0411 | Unhandled exception in commit recovery Perform LICIP08. | AJDG301 |
0412 | Unhandled exception in commit initialization Perform LICIP08. | AJDG301 |
0413 | Rebuild of recovery object index failed Perform LICIP08. | AJDG301 |
0414 | Install of operating system failed on read from media Perform LICIP08. | FI00300 |
0415 | Create user profile failed Perform LICIP08. | AJDG301 |
0417 | Initiating the initial process failed Perform LICIP08. | AJDG301 |
0418 to 0419, 0420 | The information loaded from the install media is not valid Perform LICIP08. | AJDG301 |
0421 | Bad return code creating a queue or message Perform LICIP08. | AJDG301 |
0422 | The Load/Dump command failed Perform LICIP08. | AJDG301 |
0439 | Opening the IPCF connection failed Perform LICIP08. | AJDG301 |
0440 | Termination code is not valid Perform LICIP08. | AJDG301 |
0441 | Power off system command failed Perform LICIP08. | AJDG301 |
0443 | Programmed IPL command failure Perform LICIP08. | AJDG301 |
0446 | Error during machine termination Perform LICIP08. | AJDG301 |
0447 | Failure to reach MI boundary Perform LICIP08. | AJDG301 |
0449 | Exception in MI boundary manager Perform LICIP08. | AJDG301 |
0506 | Attempt to destroy a task with critical flag on Perform LICIP08. | AJDG301 |
0607 | Maximum stack size exceeded in process or task Perform LICIP08. | AJDG301 |
0620 | Event management index is not usable Perform LICIP08. | AJDG301 |
0650 | Resource management segment could not be created or extended A main store dump was initiated. Words 2 to 9 of this SRC contain additional diagnostic information. Record SRC words 1 through 9. Perform a system IPL and collect the Product activity log and main store dump and provide them along with the recorded SRC information to IBM Service Support. The problem may also be that there is not enough auxiliary storage. | AJDG301 |
0801 | Invalid LID directory detected During system IPL, the LIDMgr detected an I/O failure or media failure while trying to read the LID directory. Perform LICIP08. | FI00070 FI00300 AJDG301 |
0802 | LID directory unusable During system IPL, the LIDMgr detected that the LID directory and associated load source is not usable. Reinstall the Licensed Internal Code by using Utilities to install and restore Licensed Internal Code. For more information, contact IBM Service Support. | AJDG301 |
0901 | The LinkLoader has found its bad flag ON This reference code is usually the result of a system termination while the LinkLoader is performing its work. Reinstall the Licensed Internal Code by using Utilities to install and restore Licensed Internal Code. | |
0902 | Unable to perform programmed IPL The LinkLoader was not successful in performing a programmed IPL. Perform a system IPL. If the problem persists, examine the main storage dump and determine the reason for the failure of the programmed IPL. | |
1001 | Enqueuing a task to the TDQ which is already enqueued on TDQ Perform LICIP08. | AJDG301 |
1103 | MISR not readable; must be readable for Normal Mode install MISR is not readable. Perform a manual install to reinitialize the system. | |
1104 | Failure reading media or not install media Determine that correct install media is loaded. If correct install media is installed, media could be corrupt. Obtain another copy of the install media and reattempt the install. If the install still fails, contact your service representative. | |
1201 | Critical database segment could not be created Perform LICIP08. | AJDG301 |
1204 | Error in constraint enforcement Perform LICIP08. | AJDG301 |
1210 | Object not found in the in-use table Perform LICIP08. | AJDG301 |
1215 | Error in critical code sequence Perform LICIP08. | AJDG301 |
1219 | A back leveled driver has been detected Perform LICIP08. | AJDG301 |
1604 | Not able to create APPN task An error occurred during task creation which requires a power off of the system. Perform LICIP08. | AJDG301 |
1724 | An attempt to create a segment failed The create could fail for two reasons:
| AJDG301 |
1730 | An IPL is needed to restore system performance Licensed Internal Code has detected a condition that is impacting system performance. System operation can continue, but system performance may be noticeably reduced until the next IPL. Look at the Product Activity Log entry, and find the value at offset x'000180'. If the value equals x'00000122', the error was caused by too much processor memory being installed. For more information, contact IBM Service Support. | GG4PL01 |
3000 | Logical partition service function Main Storage Dump. Copy the current main storage dump to media. For more information on how to copy a Main Storage Dump, refer to the iSeries Service Functions Information (see "Copying a Main Storage Dump" under "Working with Storage Dumps"). | AJDG301 |
41FC | Installation of LIC failed Words 12 and 13 of this SRC contain additional diagnostic information. Install LIC using physical media. To determine what caused the failure, collect SRC information and contact your next level of support. | SVCDOCS |
41FD | Installation of LIC failed A main store dump was initiated. Words 12 and 13 of this SRC contain additional diagnostic information. To recover the partition using the previously installed LIC, perform a B-mode IPL. You can then re-try the installation of LIC. Otherwise, install LIC using physical media. To determine what caused this failure, collect SRC information and main store dump and contact your next level of support. | SVCDOCS |
4401 | Missing DASD units. Copy the current main storage dump to media. For more information on how to perform a Main Storage Dump, refer to iSeries Service Functions information (see "Copying a Main Storage Dump" under "Working with Storage Dumps"). | |
4402 | Missing DASD units. Copy the current main storage dump to media. Then exit the Main Storage Dump Manager. For more information on how to perform a Main Storage Dump, refer to iSeries Service Functions information (see "Copying a Main Storage Dump" under "Working with Storage Dumps"). | |
4403 | Storage Management failed to reach full paging. Copy the current main storage dump to media. For more information on how to perform a Main Storage Dump, refer to iSeries Service Functions information (see "Copying a Main Storage Dump" under "Working with Storage Dumps"). | |
4404 | Auto copy failed or not attempted. Copy the current main storage dump. If copying to system ASP, existing copies may need to be deleted or renamed. Then exit the Main Storage Dump Manager. For more information on how to perform a Main Storage Dump, refer to iSeries Service Functions information (see "Copying a Main Storage Dump" under "Working with Storage Dumps"). | |
4405 | System ASP threshold exceeded after auto copy done. Delete other system ASP copies or exit the Main Storage Dump Manager and then from DST copy the Auto Copy to media and then delete the Auto Copy in system ASP. | |
4420 | MSD Manager not configured to save dump information The platform produced dump data, but the Main Storage Dump (MSD) Manager was not configured to automatically copy the dump to an Auxiliary Storage Pool (ASP). The dump will be lost if the system power is lost. Use MSD Manager to manually copy the current platform dump to media or an ASP. | |
4421 | Insufficient space in the ASP to store a platform dump The platform produced dump data, and the Main Storage Dump (MSD) Manager was configured to automatically copy the dump to an Auxiliary Storage Pool (ASP), but there was not sufficient free space available in the ASP. The dump will be lost if the system power is lost. Manually copy the current platform dump from the platform by performing one of the following:
| |
4422 | A platform dump is saved in MSD Manager The platform produced dump data. The dump data was copied to the Main Storage Dump (MSD) Manager. | PLDUMP |
4700 | Processor On Demand error detected. Processor on Demand Data Block key is not valid. Replace the Processor Capacity card. | CTLPNCD |
4701 | Processor On Demand error detected. Processor On Demand Data Block contains data that does not match the expected data. Contact your service provider. | AJDG301 |
4703 | Processor On Demand error detected. Processor On Demand Serialization has failed during IPL. Contact your service provider. | AJDG301 |
4710 | Processor On Demand error detected. SPCN communication failure during Processor On Demand. Look in the Product Activity Log for other SPCN errors and perform the actions indicated for those errors. | SPNLCRD |
4712 | Processor On Demand error detected. Correct any Processor Capacity card or SPCN failures. | CTLPNCD |
4713 | Incorrect Processor Capacity Card installed. The Processor Capacity Card is the failing item since it has been swapped in from a different system. Put the Processor Capacity Card back in the system it came from, and reinstall this system's original Processor Capacity Card. | CTLPNCD |
4714 | The CUoD data is not present. A problem may exist. The Processor Capacity Card was changed and there may be a problem. If the system did have any activated standby processors before the Processor Capacity Card was replaced, then new processor on demand activation codes must be obtained to restore the previous activations. Contact your service provider. | |
4715 | Processor On Demand error detected. Correct any Processor Capacity card or SPCN failures. | CTLPNCD |
4730 | Processor On Demand error detected. Processor On Demand standby processors are in use. Contact your service provider. | AJDG301 |
4731 | Processor On Demand error detected. The Processor On Demand Trial Activation period is not valid. Contact your next level of support. | AJDG301 |
4733 | Processor On Demand error detected. Contact your service provider. | AJDG301 |
4740 | Processor On Demand error detected. The Processor On Demand Activation code just entered is not valid. Contact your next level of support. | AJDG301 |
4741 | Processor On Demand error detected. An invalid Processor On Demand Activation code has been entered more than 5 consecutive times. Contact your service provider. | AJDG301 |
4745 | Processor Capacity card replaced on activated POD system. Contact IBM Support to order a replacement Processor On Demand activation code. | |
4747 | 1 hour left in POD 14 day Trial Activation Period. If a new activation code was purchased, it should be entered now. Otherwise, the system will revert back to its previous activation state at the end of the Trial Activation Period. | |
5001 | DST received no response from a work station controller The workstation I/O processor for the system or partition console did not respond. Perform RTRIP01 to determine which Isolation procedure to perform. | FI00380 AJDG301 |
5002 | DST problem attempting to use the system console A code problem occurred during an attempt to use the system console. Perform LICIP03. | AJDG301 FI00380 |
5003 | Service program failed The ASCII system console failed to respond. | FI00320 FI00602 UG4USR1 AJDG301 FI00380 |
5004 | DST console failed to respond The system console failed to respond. Perform RTRIP02 to determine which isolation procedure to perform. | FI00320 FI00602 UG4USR1 AJDG301 FI00380 |
5005 | Service program failed The workstation adapter system console failed to respond. Perform WSAIP01. | FI00320 FI00602 UG4USR1 AJDG301 FI00380 |
5007 | Service program failed The workstation adapter console failed to respond. Perform RTRIP07 to determine which isolation procedure to perform. | FI00320 FI00602 UG4USR1 AJDG301 FI00380 |
5008 | DST console failed to respond Perform OPCIP03. | FI00719 |
5010 | IPL service function ended abnormally Perform LICIP04. | AJDG301 |
5082 | DST lost contact with the console A service program lost contact with the system console. Perform RTRIP03 to determine which isolation procedure to perform. | AJDG301 UG4USR1 |
5083 | IPL service function ended abnormally A service program lost contact with the system console. Perform TWSIP01. | AJDG301 UG4USR1 |
5090 | System startup failed in unattended IPL mode Perform the following: | FI00580 FI00500 FI00301 FI00021 FI00065 AJDG301 |
5092 | System is in DASD migration mode "Install Licensed Internal Code" and "Upgrade Load Source" was specified but the key is not in the manual position. Change the key position to manual and perform a system IPL. | |
5094 | IASP detected a failure during the vary on operation Perform LICIP12. | SVCDOCS |
50FF | DST unrecoverable program error Perform LICIP03. | AJDG301 FI00380 |
5120 | System LIC detected a program exception System LIC detected a programming problem. If performance or other system degradation is occurring, the system may be operating with reduced resources. Check the Product activity log for related entries. If this reference code is logged with a Class of Informational, then no action is required. Otherwise, perform LICIP01. | AJDG301 FI00130 |
5121 | System LIC program exception occurred System LIC detected a programming problem for which a main storage dump may have been initiated. A problem log entry may be generated for this ref code. Perform LICIP01. | AJDG301 |
5122 | System LIC program exception occurred System LIC detected an IOP programming problem for which an IOP dump may have been initiated. Perform LICIP01. | FI00130 AJDG301 FI00131 |
5123 | System LIC program exception occurred System LIC detected an interface problem with the IOP or an IOP programming problem for which an IOP and main storage dump may have been initiated. Perform LICIP01. | FI00130 AJDG301 FI00131 |
5126 | Addressed device failed to respond to selection | DISKDRV STORIOA DISKTRY FI01106 FI01140 FI01141 DEVTERM BACKPLN |
5127 | IOP timed out a disk command | DISKDRV STORIOA FI01106 DISKTRY FI01140 FI01141 DEVTERM BACKPLN |
5128 | I/O processor failure | FI01112 FI01107 |
512D | An IOP dump was initiated Copy the IOP dump entry and any related entries from the Product Activity Log to suitable media, and give to an IBM service representative. | |
512E | System LIC program exception occurred The system was in a D IPL mode when the problem was detected. A main storage dump was not taken. Perform LICIP01. | AJDG301 FI00130 |
5206 | System LIC detected a missing IOP LIC code load System LIC detected a missing IOP LIC code load during IPL of the IOP. This indicates that either the IOP code load is not installed on the system load source device or that system LIC was unable to successfully read that load from the load source device. Perform LICIP01. | UG4USR1 |
5209 | System LIC detected an IOP timeout during IOP IPL Verify that all IOP cable connections are secure, and check tape and other non-disk devices and media to verify that they are in a ready state. Perform LICIP01. | UG4USR1 FI00130 AJDG301 |
5219 | System LIC program exception occurred An IOP signalled to system LIC that it had entered a critical internal state. LIC automatically attempted to restart the IOP. This reference code is logged for information only. No action is required. | FI00310 FI00318 FI00065 FI00130 AJDG301 |
5275 | The system issued a reset/reload to the IOP. System Licensed Internal Code detected that an IOP Reset/Reload has occurred, and that the IOP successfully recovered. Users who were signed on to a Workstation device under the IOP will need to sign back on. Any LAN/WAN communications lines under the IOP will need to be restarted. Tape/Optical devices under the IOP may need to be varied back on. To determine the cause of the IOP Reset/Reload, check the Product Activity Log for additional entries logged with the same System Log ID, and perform any actions indicated for those errors. | |
5276 | IOP Reset was issued LIC has detected a problem with the Service Processor IOP and has reset it but has not initiated reload of the Service Processor. If the load source is mirrored, some system operations may be able to continue normally. However, some system service operations have been suspended and the system should be scheduled for power down as soon as possible. Perform RTRIP08. | AJGLD01 AJDG301 FI00021 |
5310 | System LIC program exception occurred System LIC detected a logical partition configuration data consistency error. Copy the Product Activity Log data for this error and any related entries and contact your next level of hardware service support. | LPARSUP |
5311 | System LIC program exception occurred LPAR configuration data does not match current system configuration. The system will not IPL past DST until the problem is corrected. Following is a list of problems which may have caused this SRC to be reported:
| LPARSUP |
5312 | System LIC program exception occurred LPAR configuration data informational error. The LPAR configuration data was found to be or inconsistent on a secondary partition's load source. The data was automatically updated to the current system level. | |
5313 | System LIC program exception occurred LPAR configuration data informational error. The LPAR configuration data was found to be inconsistent on a primary partition and could only be corrected with an older copy of the data. | LPARCFG |
5320 | Incorrect hardware configuration detected. An I/O Adapter used by a guest partition is located in a card slot on the same PCI bridge set as an I/O Processor. Guest partition data may be lost if any of the following occur:
| |
5340 | Secondary partition not running at optimum. Check the Primary partition's Product Activity Log for system processor entries from approximately the same time. Perform the actions indicated for those entries. | |
5341 | Secondary partition not running at optimum. Check the primary partition Product Activity Log for system memory entries from approximately the same time. Perform the actions indicated for those entries. | |
5342 | Secondary partition not running at optimum. Check the Primary partition's Product Activity Log for system processor entries from approximately the same time. Perform the actions indicated for those entries. | |
5343 | Secondary partition not running at optimum. Check the Primary partition's Product Activity Log for system memory errors from approximately the same time. Perform the actions indicated for those entries. | |
5344 | Secondary partition not running at optimum. The interactive performance specified in the configuration data for this partition could not be met. Contact your next level of support. | LPARSUP |
5350 | Secondary partition software release not supported. The logical partition software version is outside the supported release delta. Check the Release Delta from the Primary partition "Display Partition Release Level" screen. Check the LPAR documentation for the release level of the Primary partition and determine what the supported Release Delta is. | |
5380 | System LIC program exception occurred Record the Product Activity Log (PAL) hex data for this SRC or print the PAL entry. Contact your next level of support. | LPARSUP |
5390 | System LIC program exception occurred Record the Product Activity Log (PAL) hex data for this SRC or print the PAL entry. Contact your next level of support. | LPARSUP |
5505 | The copying of DASD log data to the IOP log was successful IOP log data can be copied to a spool file for examination by the development lab. | |
5555 | SLIC I/O DASD subsystem error recovery in progress. | |
5600 | Unrecoverable read error VPD data could not be read. Look for other errors implicating hardware. There is no way to know what VPD read has failed, but the resource is not useable and should generate an error. If no such error occurred, call your next level of support. | SVCDOCS |
6900 | System bus error Contact your next level of support. | FI00065 AJDG301 |
6901 | Bus Expansion Adapter card failed Contact your next level of support. | LBUSADP AJDG301 |
6902 | Bus Expansion Adapter card failed Contact your next level of support. | FI00203 AJDG301 |
6905 | Optical bus failed Contact your next level of support. | FI00065 LBUSADP AJDG301 |
6906 | High Speed Link (HSL) I/O bridge failure LIC could not access part of the HSL I/O bridge VPD. The bridge and HSL loop may be prevented from becoming operational. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event viewer you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event view on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SIIOADP OPT_CLN |
6907 | High Speed Link (HSL) I/O bridge failure LIC detected invalid data in the HSL I/O bridge VPD. The bridge and HSL loop may not have become operational. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event view on the HMC, is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SIIOADP OPT_CLN |
6908 | High Speed Link (HSL) I/O bridge failure LIC data in the I/O bus vpd could not be accessed. The I/O Bus identified in the SRC may not have become operational. If there is a B600 6906 reference code, close this problem in the serviceable event view you are working with and work the 6906 error. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log or serviceable event view on the HMC or service processor is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SIIOADP OPT_CLN |
6909 | High Speed Link (HSL) I/O bridge failure LIC detected invalid data in the I/O bus VPD. The bus and resources associated with it may not be operational. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. If the serviceable event view only indicated a frame or enclosure see the locations section for the frame or enclosure type. The location of the HSL I/O Bridge will be given in the locations tables. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SIIOADP OPT_CLN |
690A | Associated adapter not found in this partition Perform LICIP16. | LICIP16 |
6910 | I/O processor failure An I/O processor timed out, returned bad status, or is not following the system bus protocol. Perform LICIP07. | FI00310 FI00318 FI00065 FI00130 AJDG301 |
6938 | Not valid system configuration detected This system model does not allow a configuration of more than three (non-OptiConnect) I/O Processors. Power down the system and remove the extra (non-OptiConnect) I/O Processor(s) so that there are three or less. Restart the system. | |
6944 | Missing or failed I/O processor cards A system bus appears to be empty. If the bus is not empty, two I/O processors in consecutive slots may be missing or broken. If there are broken I/O processors, then another more serious SRC has occurred. Otherwise find the bus number for this failure from the Product activity log and use the system configuration list to verify the configuration of the I/O processors on that bus. | FI00317 FI00316 AJDG301 |
6960 | Multi-adapter bridge card slot error, do not use card slot Slot unavailable due to 64 bit card in adjacent slot. One of the messages documented with the symbolic FRU will describe the problem. See the SLOTERR symbolic FRU for a list of messages and corrective actions. | SLOTERR |
6961 | Multi-adapter bridge card slot error, do not use card slot LED control failure, do not use slot. The card location is not available for use. The Failing Item with the card slot error is in the Failing Item list for this reference code. See the SLOTERR symbolic FRU for the list of messages and a further description of the problem detected by Licensed Internal Code. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log or a serviceable event viewer on the HMC is available for this problem then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. | SLOTERR MASBUS |
6962 | Multi-adapter bridge card slot error, do not use card slot Power control failure, do not use slot. If there is a Linux partition in the system, any IOPs plugged into slots owned by a Linux partition will not power on. This error will be logged. Correct the situation by removing the IOP cards. The card location is not available for use. The Failing Item with the card slot error is in the Failing Item list for this reference code. See the SLOTERR symbolic FRU for the list of messages and a further description of the problem detected by Licensed Internal Code. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log, or serviceable event view on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. | SLOTERR MASBUS |
6963 | Multi-adapter bridge card slot error, do not use card slot Power control failure, do not use slot. The card location is not available for use. The Failing Item with the card slot error is in the Failing Item list for this reference code. See the SLOTERR symbolic FRU for the list of messages and a further description of the problem detected by Licensed Internal Code. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event viewer you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log or serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. | SLOTERR MASBUS |
6964 | Multi-adapter bridge configuration change or error One of several errors or configuration problems has occurred under a Multi-adapter bridge. If you are using the Service Action Log (SAL), or the serviceable event viewer on the HMC or the service processor, then the correct FRU, description and card position(s) will be listed. Use the FRUs and descriptions in the serviceable event view you are working with to determine the problem. If you do not have access to the Service Action Log, or serviceable event view on the HMC or service processor, then word 4 of the SRC has more information. Examine the last 4 digits in word 4 to determine the problem by comparing them to the list below and using the FRU(s) listed here. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. | MABRCFG |
6965 | Multi-adapter bridge configuration change or error Card type not supported in this slot. An I/O processor or I/O adapter card type is installed in the location indicated in word 7 of the SRC. The card type is not supported in that slot under the Multi-adapter bridge. The card is unavailable. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. | MABRCFG |
6966 | Multi-adapter bridge configuration change or error I/O processor removed from multi-adapter bridge card slot. On the previous IPL an I/O processor was in the card location specified in word 7 of the SRC. The I/O processor was not detected on this IPL. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. | MABRCFG |
6967 | Multi-adapter bridge configuration change or error I/O adapter unavailable due to moved I/O processor card. The I/O adapter specified in word 7 of the SRC is not available. On the previous IPL there was an I/O processor card the adapter was assigned to. The I/O processor was not detected on this IPL. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. | MABRCFG |
6968 | Multi-adapter bridge configuration change or error IOA removed from multi-adapter bridge slot. On the previous IPL an I/O adapter was in the card slot specified in word 7 of the SRC. That I/O adapter was not detected on this IPL. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. | MABRCFG |
6969 | Multi-adapter bridge configuration change or error I/O adapter replaced by I/O processor card. On the previous IPL there was an I/O adapter in the location specified in word 7 of the SRC. This IPL LIC detected that the IOA was replaced by an IOP in that location. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. | MABRCFG |
696A | Card slot test failed Perform LICIP14. | FI00131 BACKPLN |
696B | Card slot could not be validated This can be caused by "PCI error injection policy" being set to "YES" and an I/O Processor being installed on the same Multi-adapter bridge domain as the I/O Adapter. Do one of the following: -- Using the HMC or a customer PC with a Web browser access the Advanced System Management Interface (ASMI) and disable PCI error injection policy. OR -- Vary off the I/O Adapter. Using Hardware Service manager in SST/DST, locate the I/O Adapter resource. Using concurrent maintenance on the associated packaging resource, remove the I/O Adapter and install it in a location that does not have I/O Processors on the same Multi-adapter bridge domain. OR -- Vary off the I/O Adapter. Use the concurrent maintenance option in Hardware Service Manager in SST/DST to power off all I/O Processors located on the same Multi-adapter bridge domain as the I/O Adapter. Use concurrent maintenance to power off and power on the I/O Adapter. Then use concurrent maintenance to power on the I/O Processors located on the same Multi-adapter bridge domain as the I/O Adapter. | |
6970 | High Speed Link (HSL) resource failure A system PCI bus failure was detected. Word 7 of the SRC contains the bus number. This failure can occur when a tower in an HSL loop is powered off using concurrent maintenance. If this is the case, close this problem. This error is most likely in the hardware that makes up the PCI bus, the PCI bus side of the HSL I/O bridge or the multi-adapter bridge. In some cases it may be caused by a failing IOP in the multi-adapter bridge's domain. When an IOP is causing the problem, the failing IOP cannot be identified. NOTE: This SRC can occur for the PCI bus resource on a PCI bus in an I/O expansion unit when the unit is powered off for a concurrent maintenance action. Exchange the failing items, one at a time, in the order they are listed in the serviceable event view or this document until you get to the BRDGSET or BRDGSTx symbolic FRU. If the problem still exists after exchanging the failing items up to, but not including, BRDGSET or BRDGSTx then perform MABIP03 to determine the failing I/O processor card. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log, or serviceable event view on the HMC or service processor, is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SI_PHB PRI_PCI MA_BRDG BRDGSET OPT_CLN |
6971 | High Speed Link (HSL) resource failure Failure in a multi-adapter bridge or on the bus to the card location it controls. For this reference code the failing item list presented in the Service Action Log (SAL) or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event viewer is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. Perform MABIP02 | MA_BRDG MASBUS PIOCARD |
6972 | High Speed Link (HSL) resource failure Multi-adapter Bridge (MaB) failure detected. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event viewer you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. | MA_BRDG |
6973 | High Speed Link (HSL) resource failure Multi-adapter Bridge has detected a problem in the card installed in the location specified in word 7 of the SRC. Use the FRU list in the Service Action Log (SAL), or serviceable event view you are working with. If you are working from this document's FRU list use the Symbolic FRU BRDGSET to determine the failing items. | BRDGSET SIIOADP MA_BRDG |
6974 | Multi-adapter bridge configuration change or error PCI I/O processor rejected the assignment of or the removal of an I/O adapter. The direct select address in word 7 of the SRC specifies the location of the IOA. The direct select address of the IOP is in word 5 of the SRC. See the DSA translation table and the Card positions table to determine the card locations for the IOA and the IOP. Use slot concurrent maintenance under HSM to assign or remove the IOA. | MABRCFG |
6975 | The system issued a reset/reload to the service processor Service processor error. | AJDGP01 |
6976 | Service processor failure For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or a serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event viewer is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. | SVCPROC |
6980 | Network Interface Controller (NIC) resource failure The FRU list displayed in the Service Action Log (SAL) or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SICNTRL OPT_CLN |
6981 | High Speed Link (HSL) I/O bridge failure Cycle power on the frame identified as the frame with failed HSL I/O Bridge prior to replacing FRUs. The FRU list displayed in the Service Action Log (SAL), or serviceable event view you are using, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. If you find either a B600 6982 or B600 6984 SRC logged at approximately the same time as this SRC then they were caused by the same failure. If you find a 6982 SRC logged at approximately the same time then close this problem and service the 6982 SRC. The failing item listed for this SRC is one of the failing items listed for B600 6982. If the serviceable event view's entry for this SRC has a location listed then record the location for use in servicing the 6982 SRC. NOTE: This SRC can occur for the HSL I/O Bridge resource in an I/O expansion unit when the unit is powered off for a concurrent maintenance action. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SIIOADP OPT_CLN |
6982 | High Speed Link (HSL) connection failure If this SRC is not in the Service Action Log (SAL), or serviceable event view you are using, then it is informational and/or statistical only. It does not require a service action. Otherwise: This is a connection failure on an HSL link. Perform RIOIP09 to determine the service action. | HSL_LNK SIIOADP SICNTRL REM_NIC OPT_CLN |
6983 | An invalid High Speed Link (HSL) configuration was detected An HSL loop has an invalid configuration. Word 4 of the SRC contains the program return code (PRC) which identifies the problem with the loop's configuration. Use the PRC and the FRU listed to determine the problem. If you are using the Service Action Log (SAL) or serviceable event view you are working with, the FRU description may already indicate the configuration problem. | SIRGCFG |
6984 | High Speed Link (HSL) loop status message An HSL loop has switched to its alternate path. This is an informational SRC only. Word 7 of the SRC contains the loop number in the leftmost 4 digits. The loop number is in hexadecimal format. You must convert the hexadecimal loop number into decimal format to recognize the loop number in HSM. This SRC can be caused by a tower on the HSL loop powering off. This SRC may also appear in the Service Action Log (SAL), or serviceable event viewer you are using, with a B600 6982 or B600 6981 logged at approximately the same time. In that case the other SRC is reporting a failure and this SRC is reporting that the alternate HSL path is now being used. Service the other SRC if present. | |
6985 | High Speed Link (HSL) loop status message If this SRC is not in the Service Action Log (SAL), or serviceable event view you are using, then it is informational. Use FRU SIRSTAT to determine what this SRC means. Otherwise, continue with the following steps: This error can appear as a serviceable event when a tower, or I/O unit or another system in the loop did not complete powering on before LIC on this system checked this loop for errors. Search the Product Activity Log (PAL) for the last B600 6985 SRC logged for this loop and use FRU SIRSTAT to determine if this error requires service. If the last entry indicates the loop is functioning (determined by FRU SIRSTAT) then no service action is required, close this problem There may be multiple B600 6985 logs with xxxx 3205 in word 4 errors for the same loop resource in the serviceable event view. This is caused by retry and recovery attempts. If there is a B600 6985 with xxxx 3206 or xxxx 3208 in word 4 after the above B600 6985 entries in the PAL, then the recovery efforts were successful. If this is the case, close all the B600 6985 entries for that loop resource in the serviceable event view.
If this SRC appears in the Service Action Log (SAL), or the serviceable event view you are using, with the Symbolic FRU HSL_LNK or HSLxxxx listed as a FRU, then perform problem isolation procedure RIOIP01. Otherwise exchange the FRUs listed in the serviceable event view. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. | SIRSTAT HSL_LNK SIIOADP SICNTRL OPT_CLN |
6986 | System bus error During IPL, system LIC detected an HSL I/O bridge that was already initialized. The bridge should have been in a flushed and unintialized state after powering on. There is a problem with SPCN components that prevented the tower from powering off after a previous power off was issued. The tower will not be configured for this IPL. This reference code is equivalent to 1xxx 90F0. When referring to the "CBLALL" symbolic FRU in the Failing Item list, perform the "CBLALL" procedure using reference code "90F0". Word 5 of the SRC identifies the frame. Determine the frame by breaking down word 5: Word 5 -> xxxx xxNN where: NN is the frame number in hexadecimal format. | TWRCARD CBLALL |
6987 | High Speed Link (HSL) connection failure Failures are occurring on the HSL link. There may be B600 6982 errors logged on the same loop and about the same time as this error. Close those errors and continue to correct the problem by working this error.
2. If the connection is optical, clean the connections at both ends of the cable. See OPT_CLN. If the error persists, replace the FRUs in the Service Action Log (SAL), serviceable event view you are using. 3. If the error persists, replace the FRUs at each end of the cable starting with the FROM FRU listed in the serviceable event view you are using.
| HSL_LNK OPT_CLN |
6990 | Service processor failure The FRU list displayed in the Service Action Log (SAL), or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. | SVCPROC |
6991 to 6992 | Service processor failure | AJDGP01 |
6993 | Service processor failure A failure occurred with the service processor hardware or the service processor LIC. The FRU list displayed in the Service Action Log (SAL), or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. | SVCPROC AJDGP01 |
6994 | Service processor failure The FRU list displayed in the Service Action Log (SAL) or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. | SVCPROC |
699C | Wrap plug is installed on Bus Expansion Adapter card This reference code is for information only. It indicates the presence of a wrap plug on the local optical link card. | |
69A8 | Informational bus reference code This reference code is for information only and might include the following:
| |
69B8 | Bus hardware configuration problem Contact your next level of support. | FI00187 AJDG301 |
69C1 | A failure occurred on another system Contact your next level of support. | FI01040 FI00206 FI00182 AJDG301 |
69C2 | Information only, no service action required. HSL OptiConnect normal connection to another system or partition. This reference code is informational only. HSL OptiConnect has established connection normally. The local system or partition is participating in HSL Opticonnect with other systems or partitions on the same HSL loop. | |
69C3 | Information only, no service action required. Opticonnect normal remote disconnection from OptiConnect participation. This reference code is informational only. HSL Opticonnect disconnected normally from a remote node. The local system or partition has stopped participating in HSL Opticonnect with the remote system or partition on the same HSL loop. Possible reasons include:
| |
69C5 | I/O processor failure Contact your next level of support. | FI00206 FI01040 AJDG301 |
69C6 | Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. The problem is most likely with the remote system or partition. Intervention at the remote system is most likely required. Examine both the local and remote HSL OptiConnected systems or partitions for problems on this HSL loop. Possible reasons include: A fatal error in software or hardware in the remote system or partition or a power failure in the remote system. If there was not a complete HSL loop before this error occurred then a failure or power down in an HSL component between the local system or partition and the remote system or partition could have caused this error. Check for a problem with: an HSL cable, HSL I/O bridge or a power problem in an expansion I/O tower or unit on this loop. Examine the Service Action Log (SAL), or serviceable event view you are using on the local system or partition for HSL failures on the same HSL loop at approximately the same time this error occurred. Examine the remote system or partition for problems. If the remote system or partition is powered on and IPL'd then examine the Service Action Log (SAL), or serviceable event view you are using, on the remote system or partition for problems on the same HSL loop at approximately the same time this error occurred. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers. When the remote system is IPL'd it will automatically reconnect with this system or partition. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support. | REM_SYS |
69C7 | Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. LIC will attempt to recover from the error. Intervention at the local or remote system or partition may be required. Possible causes are: time out, hang or hardware failure. The problem may be with: the local system or partition or the remote system or partition. If there was not a complete HSL loop before this error then a failure or power down in an HSL component between the local system or partition and the remote system or partition could have caused this error. Check for SRCs with FRUs like: HSL cables, HSL I/O bridge or a power problem in an expansion I/O tower or unit on this loop. Examine the SAL or serviceable event view you are working with on the local system or partition for failures on the same loop, or with the Network Interface Controller at approximately the same time. Examine the remote system or partition for problems. Correct any HSL or NIC problems you find with the remote and local systems or partitions. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log (PAL) information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support. | REM_SYS LOC_SYS |
69C8 | Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. All of the HSL OptiConnect connections on this loop will be in a failed state. LIC will attempt to recover from the error. Intervention at the local or remote system or partition may be required. Possible causes are:
Examine the remote system or partition for problems. Examine the Service Action Log (SAL), or serviceable event view you are using, on the remote system or partition for problems on the same HSL loop or with the Network Interface Controller at approximately the same time this error occurred. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on all systems or partitions. Be sure to record all words in the SRCs. Contact your next level of support. | REM_SYS LOC_SYS AJDG301 |
69C9 | Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an failure in a LIC virtualized bus unit. LIC will attempt to recover from the error. Possible causes are:
Examine the remote system or partition for problems. Examine the Service Action Log (SAL), or the serviceable event view you are using, on the remote system or partition for HSL Opticonnect problems that occurred at approximately the same time this error occurred. Collect all the Product Activity Log information for this failure on all systems and partitions on this HSL loop. Be sure to record all words in the SRCs. Contact your next level of support with the information you have collected. | AJDG301 REM_SYS LOC_SYS |
69CF | Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. LIC internal error. All systems participating in HSL OptiConnect will be disconnected. The system must be re-IPL'd to recover. Before re-IPL'ing the system initiate a main store dump. After getting the dump, examine the Service Action Log (SAL), or serviceable event view you are using, on the local system or partition for HSL Opticonnect failures that occurred at approximately the same time this error occurred. Examine the remote systems or partitions for problems. Examine the Service Action Log (SAL), or serviceable event view you are using, on the remote systems or partitions for HSL Opticonnect problems that occurred at approximately the same time this error occurred. Collect all the Product Activity Log information for this failure on all systems and partitions on this HSL loop. Be sure to record all words in the SRCs. Contact your next level of support with the information you have collected. | AJDG301 |
69D0 | Bus Expansion Adapter card failed Contact your next level of support. | FI00182 FI00055 AJDG301 |
69D8 | Bus Expansion Adapter failed Contact your next level of support. | FI00182 FI00203 FI00055 LBUSADP AJDG301 |
69D9 | Host Ethernet Adapter (HEA) failure Firmware detected a hardware failure in the Host Ethernet Adapter (HEA). | HEA |
69DA | System log entry only, no service action required | |
69DB | LIC failure A Licensed Internal Code error occurred. The partition will continue to run with this Host Ethernet Adapter (HEA) disabled. Perform a partition dump and then IPL the partition to recover the HEA. Send the partition dump to your next level of support. | SVCDOCS |
69DC | The HEA is not connected to the Ethernet switch The Host Ethernet Adapter (HEA) is not connected to the Ethernet switch. If the HEA connection is not needed, no service action is required. If the HEA connection is needed, verify that the cable is connected and the switch is powered on. After repairing the problem, verify that the connection has been restored. | |
69DD | The HEA connection to the Ethernet switch has been restored System log entry only, no service action required. | |
69DE | HEA Media Interface Adapter Failure Firmware detected a failure in the HEA Media Interface Adapter. | HEA AJDG301 |
69E0 | Bus Expansion Adapter card failed Contact your next level of support. | FI00203 AJDG301 |
69E8 | Bus Expansion Adapter failed Contact your next level of support. | FI00203 FI00205 FI00057 AJDG301 |
69F0 | Bus Expansion Adapter failed Contact your next level of support. | FI00180 FI00182 FI00203 FI00056 FI00205 LBUSADP AJDG301 |
69F8 | Bus Expansion Adapter failed Contact your next level of support. | FI00180 FI00203 FI00182 FI00186 FI00057 AJDG301 |
7001 | ISDN call in rejected | GG4COMM |
7002 | Lines not selected | GG4COMM |
7003 | Network interfaces not selected | GG4COMM |
7004 | TCP/IP informational error This reference code is logged when the TCP/IP Attribute "Log Protocol Errors" is set, and the TCP/IP System LIC "silently discards" an inbound datagram. "Silently discard" is defined to mean discard the received datagram without reporting an error to the originating host device. Examples of such datagrams are those with checksums or destination addresses which are not valid. This reference code is for information only. Normally no action should be taken as a result of this reference code. It is generated in order to assist with remote device or TCP/IP network problem determination. | |
7055 | Statistics were logged, no service action required This reference code is logged for information only. | |
7100 | APPN session initiation attempt has timed out This reference code is used to indicate that LIC timed out on a request to initiate a session. The user must run problem analysis for this reference code. If this indicates a software problem, the user should dial IBM Software Support for assistance. The Problem Determination Procedure (PDP) will indicate whether the original timeout condition still exists and what the corrective actions should be. | AJDG301 GG4PL03 GG4PL01 GG4PL02 |
7101 | APPN session initiation attempt has failed This reference code is used to indicate that LIC attempted to satisfy a session initiation request, but some failure condition was detected by LIC. The failure condition could be a configuration or operational problem in the network. The user must run problem analysis for this reference code. If this indicates a software problem, the user should dial IBM Software Support for assistance. The Problem Determination Procedure (PDP) will indicate whether the original timeout condition still exists and what the corrective actions should be. | GG4PL04 GG4PL05 GG4PL06 AJDG301 |
7102 | APPN CP-CP session ended. | |
7201 | A utility failure occurred. This reference code is for information only. The Uninterruptible Power System (UPS) is reporting a utility failure. | |
7202 | Utility power restored. This reference code is for information only. The Uninterruptible Power System (UPS) is reporting that utility power has been restored. | |
7203 | A battery low condition was detected. This reference code is for information only. The Uninterruptible Power System (UPS) is reporting a battery low condition. | |
7204 | Uninterruptible Power System reported a bypass active This reference code is for information only. The Uninterruptible Power System (UPS) is reporting a bypass is active. | |
7205 | Battery low condition was reset. This reference code is for information only. The Uninterruptible Power System (UPS) is no longer reporting a battery low condition. | |
7206 | UPS reported bypass no longer active This reference code is for information only. The Uninterruptible Power System (UPS) is no longer reporting a bypass active condition. | |
7207 | Battery Power Unit needs service The replacement period for BPU 1, installed in the System Unit, has been exceeded. | FI00315 |
7208 | Battery Power Unit needs service The replacement period for BPU 2, installed in the System Unit, has been exceeded. | FI00315 |
7209 | Battery Power Unit needs service The replacement period for BPU 1, installed in the Expansion Unit, has been exceeded. | FI00315 |
720A | Battery Power Unit replacement dates do not match The replacement dates for one of the Battery Power Units do not match. Run "Display Hardware Configuration" and verify that the dates match the labels on the batteries. | |
7701 | SCSI jumper card was not detected. | 21H7625 BACKPLN |
7702 | Incorrect SCSI jumper card detected | 21H7625 |
7703 | System LIC detected a program exception Storage Management detected a DASD datacheck condition and the defective sector was reallocated. Perform a system IPL to restart the system. | |
7704 | General failure detected by HRI component. | AJDG301 |
7777 | Hardware configuration change detected A hardware resource is missing. The resource reported in to the system on a previous IPL, but has not reported in on the current IPL. This could occur for several different reasons. | |
8000 | An external storage subsystem disk unit connection failed Look for other errors in the Service Action Log (SAL), or serviceable event view you are working with, and fix them. | |
8001 | An external storage subsystem disk unit connection failed Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. | |
8002 | Maximum number of redundant connections exceeded An attempt to activate a connection from another I/O adapter to an external storage subsystem disk unit failed because the maximum number of connections are already active for this disk unit. No action required. | |
8003 | External storage subsystem disk unit connection was restored No action required. | |
8004 | An external storage subsystem disk unit connection failed Could not read configuration information from the disk unit. Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. | |
8005 | High performance connection failed A high performance connection to an external storage subsystem disk unit failed. There are still two or more external storage subsystem disk unit connections, but performance might be degraded. Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. | |
8006 | High performance connection failed A high performance connection to an external storage subsystem disk unit failed. There is still one more external storage subsystem disk unit connection, but performance might be degraded. Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. | |
8007 | High performance connection was restored A high performance connection to an external storage subsystem disk unit was restored. Performance is no longer degraded. No action required. | |
CF00 | Permanent error on optical device. A type D IPL terminated because of an optical load source device failure. If the optical load source is an external optical device, check the cables. If that does not correct the problem, replace the optical device. If the optical load source is an internal optical device, replace the optical device. If the optical load source is a virtual device, ensure it is set up correctly. | SVCDOCS |
CFFC | Optical library device condition not expected The optical disk drive addressing within the optical library is incorrect. This error is likely to be the result of faulty cabling or switch setting following service to an optical library. Contact your hardware service provider. | OPTLCBL DRVSWCH |
CFFD | Optical drive failure | OPTLDRV |
CFFF | Media determined to be bad in Optical library | |
F103 | Main storage dump must be copied for service. Perform LICIP01. | |
F104 | Logical partition service function Main Storage Dump. The hypervisor terminated a partition with an unresponsive Operating System. A Main Store Dump must be done for service. Call your next level of support when the dump is complete. Perform LICIP01. | |
F105 | Licensed Internal Code detected error | NEXTLVL |
FDC0 | LIC program reported informational error This reference code is logged for information only. No action required. | |
FDC5 | LIC program failed and data was captured This reference code indicates first failure data capture (FFDC) data was collected for a problem reported by licensed internal code. The user should dial IBM Software Support for assistance. | GG4FFDC |
Table 3. Licensed Internal Code failing items details
Failing Item | Description | Document Description |
21H7625 | Incorrect, defective or missing SCSI jumper card | Repair and Parts; removal and installation procedures |
AJDG301 | Licensed Internal Code | Service Functions; APAR or LICTR |
AJDGP01 | Service Processor LIC | Repair and Parts; removal and installation procedures |
AJGLD01 | I/O card Licensed Internal Code | Service Functions; APAR or LICTR |
BACKPLN | Card enclosure or backplane | See the service documentation for instructions. |
BRDGSET | PCI Bridge set, Multi-adapter bridge domain cards | See the service documentation for instructions. |
BSTWRPL | FC 9074, FC 9079 Base I/O tower card with service processor | See the service documentation for instructions. |
CBLALL | SPCN cable to HSL connected I/O tower | See the service documentation for instructions. |
CTLPNCD | System Unit Control Panel Card Assembly | See the service documentation for instructions. |
CVTCARD | HSL (SI) I/O Adapter for FC 5076 SPD migrated tower | See the service documentation for instructions. |
DEVTERM | Terminating plug | See the service documentation for instructions. |
DISKDRV | Disk Drive and Logic Card | See the service documentation for instructions. |
DISKTRY | Disk unit tray | See the service documentation for instructions. |
DRVSWCH | Drive address switch | See the service documentation for instructions. |
GG4COMM | Communications failure | |
GG4FFDC | LIC program failed and data was captured | |
GG4PL01 | System performance problem | |
GG4PL02 | Network performance problem | |
GG4PL03 | Switched link activation failure message not answered | |
GG4PL04 | Transmission groups in the network must be activated | |
GG4PL05 | Class-of-service specified does not provide a route | |
GG4PL06 | COS acceptable TGs and nodes do not exist for the route | |
HEA | Host Ethernet Adapter | See the service documentation for instructions. |
HSL_LNK | HSL (SI) cable or connection or interposer | See the service documentation for instructions. |
LBUSADP | SPD local bus adapter, where optical daughters plug | See the service documentation for instructions. |
LICIP16 | LIC Isolation Procedure | Service Functions; APAR or LICTR |
LOC_SYS | Local HSL Opticonnect system or partition. | Local HSL OptiConnect system |
LPARCFG | "LPARCFG" LPAR configuration - processors, memory or ld src | See the service documentation for instructions. |
LPARSUP | "LPARSUP" LPAR complex problem, call next level of support. | See the service documentation for instructions. |
MABRCFG | Multi-adapter bridge configuration error or change | See the service documentation for instructions. |
MASBUS | Multi-adapter bridge secondary bus or card slot | See the service documentation for instructions. |
MA_BRDG | Multi-adapter bridge high level symbolic | See the service documentation for instructions. |
NEXTLVL | Call your next level of support for assistance | Rio PIP 55 |
OPTDRIV | Optical Disk Drive | See the service documentation for instructions. |
OPTLCBL | Optical Library drive cabling | See the service documentation for instructions. |
OPTLDRV | Optical Library optical drive | See the service documentation for instructions. |
OPT_CLN | Fiber optic cleaning kit | Fiber optic cleaning kit |
PIOCARD | PCI nodes adapter card, IOP or IOA | See the service documentation for instructions. |
PLDUMP | Platform dump occurred | See the service documentation for instructions. |
PPCIMIN | Primary PCI bus in 5075 I/O tower | See the service documentation for instructions. |
PPCISYS | Primary PCI bus in a system unit | See the service documentation for instructions. |
PPCITWR | Primary PCI bus in a 5074 I/O tower | See the service documentation for instructions. |
PRI_PCI | Primary system PCI bus to a MaB, high level symbolic | See the service documentation for instructions. |
REM_NIC | A remote NIC in a cluster. | |
REM_SYS | HSL opticonnect remote system or partition. | Remote HSL OptiConnect system |
SIADPCD | High Speed Link (SI) I/O adapter card in FC 5074 I/O tower | See the service documentation for instructions. |
SICNTRL | HSL (SI) controller, high level symbolic | See the service documentation for instructions. |
SIIOADP | High Speed Link (SI) I/O adapter, high level symbolic | See the service documentation for instructions. |
SIRGCFG | SI ring invalid configuration | See the service documentation for instructions. |
SIRSTAT | System Interconect ring status | See the service documentation for instructions. |
SI_CARD | HSL (SI) controller card on a system unit | See the service documentation for instructions. |
SI_PHB | PCI host bridge adapter, high level symbolic | See the service documentation for instructions. |
SLOTERR | Multi-adapter bridge slot error | See the service documentation for instructions. |
SPNLCRD | SPCN panel card | See the service documentation for instructions. |
STORIOA | Active I/O processor | See the service documentation for instructions. |
SVCDOCS | Customer engineer directed to system problem analysis | See the service documentation for instructions. |
SVCDOCS | Equipment failure; not isolated | Service Functions; APAR or LICTR |
SVCPROC | Service Processor | See the service documentation for instructions. |
SYSBKPL | System unit backplane | See the service documentation for instructions. |
TWRBKPL | FC 5075 I/O tower backplane | See the service documentation for instructions. |
TWRCARD | SPCN failing component in HSL I/O tower | See the service documentation for instructions. |
TWRPLNR | FC 5074, FC 9074, FC 9079 I/O tower PCI card planar | See the service documentation for instructions. |
UG4USR1 | Operator response required |
Mi nombre es Martín Ortega Novella, vivo en Asturias, casi toda mi vida laboral ha sido en IBM, pero ya estoy jubilado.
Siempre he utilizado Lotus Notes/Domino para mi blog, donde me he sentido más cómodo ha sido cuando estaba alojado en mi AS/400, ahora está en un iMac
Durante un año utilicé IBM WebSphere Portal Server, un gran producto pero volví a usar Lotus / Notes porque es lo que más gusta.
SIDRA400 es miembro del ESLUG (Spanish HCL Domino User Group).